Cummins C100D6C 100kW QuietConnect Series Diesel Generator (1-Phase 120/240V) - PowerGen USA
Cummins C100D6C 100kW QuietConnect Series Diesel Generator (1-Phase 120/240V) - PowerGen USA
Robust product design and testing - The Cummins generator is designed to operate under extreme environmental conditions. The generator is tested and certified per the latest EPA and UL standards, ensuring top performance in demanding environments.
Heavy-duty engines - Rugged 4-cycle industrial diesel engines deliver reliable power and a fast response to load changes. Whether you need a Cummins industrial generator or a 100kw diesel generator, this system provides unmatched reliability.
Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads, and fault-clearing short-circuit capability, all part of the advanced Cummins generator specifications.
Control system - The PowerCommand® 1.1 electronic control is standard equipment and provides total generator set system integration, including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, and auto-shutdown at fault detection. Perfect for ensuring optimal performance, even for a 100kw diesel generator setup.
Cooling system - The standard cooling package ensures reliable operation at ambient temperatures up to 122°F (50°C). Coolant heaters come standard for easy starting well below freezing, an essential feature for Cummins industrial generators.
Enclosures - The aesthetically appealing enclosure features a special design, making this one of the quietest diesel generators of its kind. With aluminum material and a durable powder coat paint, the enclosure offers top anti-corrosion performance. The generator set enclosure has been tested to withstand 180 mph wind loads, following ASCE 7-10 standards.
Fuel tanks - Two dual-wall sub-base fuel tank series are available as optional features, offering economical and flexible solutions to meet extensive code requirements. These fuel tanks enhance the efficiency of 100kw diesel generators and Cummins generators alike.
diesel fuel tanks.
|
|
|
|
Standby 60 Hz |
Model |
Model Number |
Fuel Tank |
KW |
KVA |
C20 D6 |
A063P962 |
None |
20 |
20 |
C30 D6 |
A063P964 |
None |
30 |
30 |
C50 D6 |
A063P966 |
None |
50 |
50 |
C80D6C |
A063P969 |
None |
80 |
80 |
C100D6C |
A063P987 |
None |
100 |
100 |
C20 D6 |
A063P961 |
24 Hr |
20 |
20 |
C30 D6 |
A063P963 |
24 Hr |
30 |
30 |
C50 D6 |
A063P965 |
24 Hr |
50 |
50 |
C80D6C |
A063P967 |
24 Hr |
80 |
80 |
C100D6C |
A063P977 |
24 Hr |
100 |
100 |
SPECIFICATIONS
Generator set Specifications
Model |
C20 D6 |
C30 D6 |
C50 D6 |
C80D6C |
C100D6C |
Enclosures |
|
||||
Sound |
68.4 |
69.7 |
71 |
74.6 |
74.7 |
Fuel Tank - Usable Volume |
46 gals |
74 gals |
132 gals |
260 gals |
260 gals |
|
0.97 gph |
1.62 gph |
2.38 gph |
4.00gph |
4.80 gph |
Fuel Consumption – 100% Load |
1.81gph |
2.81 gph |
4.25gph |
7.30 gph |
8.90 gph |
Controller |
PowerCommand 1.1 |
||||
|
120/240 – 1 Phase |
||||
Operating temp. range |
-40 °F to +122 °F (-40 °C to +50 °C) |
||||
|
100 Amps |
150 Amps |
250 Amps |
400 Amps |
600 Amps |
|
Standard – 6A |
||||
Governor reg. class |
|
||||
|
|
||||
|
|
||||
Frequency regulation |
|
||||
|
± 0.5% |
||||
|
FCC code Title 47 part 15 class A and B |
||||
Indicates that circuit breaker is adjustable ** - dB(A) measured at 23 ft (7 m) at full rated load |
|
Engine Specifications
Model |
C20 D6 |
C30 D6 |
C50 D6 |
C80D6C |
C100D6C |
Engine |
D220 |
QSB3.3 |
QSB5 |
||
Displacement |
2.20 L (134.1 in3) |
3.3 L (199 in3)
|
4.5 L (272 in3)
|
||
Cylinder Block |
Cast iron, in-line |
|
|||
|
550 amps |
550 amps |
550 amps |
2 x 850 amps |
2 x 850 amps |
|
50 amps |
40 amps |
50 amps |
100 amps |
100 amps |
|
12-volt, negative ground |
12-volt, negative ground |
12-volt, negative ground |
2x 12-volt, negative ground |
2x 12-volt, negative ground |
|
|
||||
|
|
Alternator Specifications
Model |
C20 D6 |
C30 D6 |
C50 D6 |
C80D6C |
C100D6C |
Design |
|
||||
Stator |
|
||||
Rotor |
|
||||
Insulation system |
|
||||
|
|
||||
|
Torque match (shunt) with PMG as option |
||||
|
|
||||
|
|
||||
Telephone Influence Factor (TIF) |
< 50 per NEMA MG1-22.43 |
||||
Telephone Harmonic Factor (THF) |
|
Accessories
- Battery heater kit A045R833 (C20D6, C30D6 & C50 D6)
- RS remote in-home display: A053K028
- Remote monitoring device: PC 500 A059Y211, PC 550 A059Y210
- Base barrier – elevated generator sets A052U603 (C80 D6C & C100D6C)
Model |
Tank |
Dim “A” mm (in.) |
Dim “B” mm (in.) |
Dim “C” mm (in.) |
Set weight* dry kg (lbs.) |
Set weight*wet kg (lbs.) |
|
Yes |
1830 (72) |
864 (34) |
1486 (58.5) |
637 (1401) |
653 (1437) |
No |
1830 (72) |
864 (34) |
1156 (45.5) |
494 (1091) |
|
|
|
Yes |
2384 (93.8) |
864 (34) |
1537 (60.5) |
790 (1738) |
811 (1784) |
No |
2384 (93.8) |
864 (34) |
1156 (45.5) |
580 (1282) |
600 (1328) |
|
|
Yes |
2384 (93.8) |
864 (34) |
1740 (68.5) |
1003 (2207) |
1024 (2253) |
No |
2384 (93.8) |
864 (34) |
1156 (45.5) |
695 (1538) |
716 (1584) |
|
|
Yes |
3016 (119) |
1016 (40) |
2108 (40) |
1505 (3309) |
1556 (3425) |
No |
3016 (119) |
1016 (40) |
1473 (58) |
1136 (2500) |
1185 (2614) |
|
|
Yes |
3016 (119) |
1016 (40) |
2108 (83) |
1505 (3309) |
1613 (3548) |
No |
3016 (119) |
1016 (40) |
1473 (58) |
1136 (2500) |
1237 (2729) |